STERILE MEDICAL DEVICES

JCM MED offers a range of sterile medical devices mainly related to IV therapy.
Do not hesitate to ask for our Technical Data Sheets.

JCM MED Intravenous Cannulas / Catheters allow the introduction or withdrawal of fluids from the human circulatory system. The short flexible and kink-resistant catheter is introduced into a blood vessel over a hollow introducer needle.
The atraumatic needle is withdrawn after introduction of the catheter into the blood vessel. The transparency of the flashback chamber allows a proper visualization of the blood flash-back.
See Instructions for Use.

IVCV seriesIV cannula / catheter with port & wings.
Gauges12-26 G
Packingsterile rigid blister
SterilisationETO
ClassIIa

IVCP seriesIV cannula / catheter without port, without wings.
Gauges12-26 G
Packingsterile rigid blister
SterilisationETO
ClassIIa

IVCW seriesIV cannula / catheter without port & with wings.
Gauges12-26 G
Packingsterile rigid blister
SterilisationETO
ClassIIa

Pen-like series1-way IV cannula with hydrophobic filter and hard shell packaging.
Gauges12-26 G
Packingsterile rigid blister
SterilisationETO
ClassIIa

JCM MED provides IV cannulas with the following features :
  • PTFE / PUR or FEP catheters
  • Clear or radiopaque catheters
  • With or without hydrophobic filters
  • Medical grade or Tyvek paper

IVCSV1 Series: PASSIVE Safety IV cannulas

The IVCSV1 series of IV cannulas are fitted with a safety feature which self activates during the needle withdrawal. This passive device provides full protection from needle stick injury.


The range covers Gauges 14-24G.


JCM MED provides IV cannulas with the following features :
  • PTFE / PUR or FEP catheters
  • Clear or radiopaque catheters
  • With or without hydrophobic filters
  • Medical grade or Tyvek paper

IV Safe ™ Series: ACTIVE Safety IV cannulas


The IV Safe ™ series of IV cannulas are fitted with a safety feature meant to withdraw the needle semiautomatically by pressing a knob that sends it into a rigid chamber where it remains enclosed. Fully enclosing the needle avoids :


  • Needle-stick injuries, potentially responsible for disease transmission (Hepatitis, H.I.V, etc.).
  • Needle breakage during disposal which can turn a tip-protected needle potentially harmful again.
  • Direct contact with blood-stained needles which are only tip-protected.
The range covers14-24G for 1-way IV cannulas
without port, without wings
18-24G for IV cannulas with port & wings
Packingblister
SterilisationETO
ClassIIa

Flowset ™ I.V. sets are supplied with or without DEHP and can be fitted with additional components or fittings such as :
  • Y injection ports (latex-free)
  • Needle-free connectors
  • One-way check valves
  • Slide or Robert clamps
  • Stopcocks
  • Fix, rotating or retractable luer lock
  • Connectors
  • Hypodermic needles …

PackingPeel pouch or PE bag
SterilisationETO
ClassIIa
See Instructions for Use
Single-chamber B.T. sets
Double-chamber B.T. sets

Transet ™ B.T. sets are supplied with or without DEHP and can be fitted with additional components or fittings such as :
  • Y injection ports (latex-free)
  • Needle-free connectors
  • Flash bulbs (latex-free)
  • Slide or Robert clamps
  • Stopcocks
  • Fix, rotating or retractable luer lock connectors
  • Connected needles with caps…

PackingPeel pouch or PE bag
SterilisationETO
ClassIIa
See Instructions for Use
Standard Extension sets
Extension sets with flow controllers
Pressure extension sets
Extension sets with Needle-free connectors
Material may vary according to the intended use. Extension sets may be fitted with additional components or fittings such as :
  • Y injection ports (latex-free)
  • Needle-free connectors
  • Slide or Robert clamps
  • Stopcocks
  • Fix, rotating or retractable luer lock connectors...

PackingPeel pouch or PE bag
SterilisationETO
ClassIIa
See Instructions for Use
The burette set is a volumetric I.V. solution administration set.
It incorporates a metered cylinder which allows an accurate administration of a certain volume of solution, thus making it a must, for example, for paediatric administration of solutions.

JCM MED burettes incorporate a float valve that prevents air intake into the lower administration tube once the burette is empty.

Volumes of the metered cylinder100ml & 150ml
PackingPeel pouch
SterilisationETO
ClassIIa
See Instructions for Use

The same models as above can be provided with needle-free connectors both on the burette cap and attached to the tubing, for safe administration of drugs without the use of a needle.

3-Way stopcocks


JCM MED 3-Way stopcocks are single-use sterile medical products meant to be used in conjunction with other devices during infusion therapy. Their main functions are :
  • To safely stop or restore an infusion flow.
  • To provide two additional ports for administration of any fluid.

- Stopcocks may be provided with a lipid-resistant formulation.
- Separate coloured pegs may be provided in the blister.
Standard pressureup to 5 bars
Packingrigid or soft blister
SterilisationETO
ClassIIa
See Instructions for Use

Injection stoppers


The JCM MED Injection stopper is a device used with a non-ported I.V. Cannula in order to avoid infection. Medicine can be injected by a syringe with a needle through the site of the injection stopper to the patient when infusion of I.V. fluid is discontinued. The injection stopper can also be used as a Luer cap.
Injection stoppers can be provided transparent or yellow coloured.
Latex-free
Packingrigid blister
SterilisationETO
ClassIIa
See Instructions for Use
Needle-free connectors provide a safe way to administer fluids, blood and medication. They greatly reduce the risk of needle stick injuries by allowing connections of a syringe to a catheter, an extension set or an infusion set, without the use of a needle.
JCM MED has developed a range of sterile needlefree devices that incorporate these connectors.
All devices are Class IIa.
See Instructions for Use.

Needle-free connectors


  • Positive & Negative pressure
  • Packing : blister
  • Sterilisation : ETO

I.V. Solution administration sets


  • With Y needle-free connector
  • Packing : peel pouch
  • Sterilisation : ETO

Extension sets


  • 1/2/3/4 way extension sets
  • Packing : peel pouch
  • Sterilisation : ETO

Burette sets


  • 2 x Needle-free access valves on the cap and on the tubing
  • Packing : peel pouch
  • Sterilisation : ETO
Disinfection caps for needle-free connectors
The disinfection cap for needle free infusion connectors is designed to allow the convenient and safe disinfection of multi-activated needle free connectors fitted on IV catheters, IV sets, CVC, Hemodialysis catheters, etc. If not removed, it can maintain a disinfected connector for up to 7 days, while acting as a physical barrier from touch and airborne contamination.


  • Thorough disinfection decreases the incidence rate of CRBSI (Catheter-Related Bloodstream Infection).
    A pad with 70% of Isopropyl alcohol covers all the surface of the inlet’s needle free connector’s septum and ensures no disinfection dead-space.
  • Its design and operation improves work efficiency by saving time, gestures, swabbing devices and increased safety. No manual swabbing required, twisting gently the cap to lock it onto the connector is enough.
  • Universal to various brands of needle free connectors.

PackingBlister
SterilisationR
ClassIIa
The Arterial Venous Fistula (A.V.F.) Set is a part of the dialysis equipment. The function of the device is to serve as a conduit for blood between blood vessel of the patient and the dialysis filter.
The device comprises an ultra-hollow needle, which is mounted on a hub that passes into a smooth kink resistant tube. At the other end of the tube there is a universal female Luer that is used to connect the device with the other part of the dialyser. The product should be such as to allow a very smooth flow of the blood & minimum pain caused during insertion.


  • Tube length : 15 or 30cm
  • Gauges : 14-18G
  • Wings : fix / rotating
  • With back eye
  • Packing : blister
  • Sterilisation : ETO
  • Class : IIa
  • See Instructions for Use


As an option, a safety clipping device may be provided to enclose the needle prior to disposal, thus preventing needle stick injuries.
Suction tubes are commonly used to draw out body fluids during thoracic or ventral surgery.
The Set usually consists in a PVC tube fitted with connectors at each end. Optionally, a Yankauer handle may be incorporated into the packaging along with this device.


Suction tubes


  • Material : PVC
  • Lengths : 180 -300cm
  • Packing : peel pouch
  • Sterilisation : ETO
  • Class : IIa
  • See Instructions for Use


Yankauer handles

Yankauer handles may also be supplied separately.
  • Material : resin
  • With / without vacuum control
  • Packing : peel pouch
  • Sterilisation : ETO
  • Class : IIa
  • See Instructions for Use